261
connected to the UPS by a USB cable.
Choose between whether the NVR will shut down or enter auto-protection mode
after AC power fails. Specify the time in minutes that the NVR should wait before
executing the option you have selected. After the NVR enters auto-protection
mode, the NVR resumes the previous operation status when the power restores.
5.Enter the “IP address” of other network UPS slaves to be notified in the event
of power failure.
6.Click “Apply All” to confirm and continue the setup for the NVR systems which
operate in network slave mode below.
Network slave mode
A network UPS slave communicates with network UPS master to receive the UPS
status. To set up your NVR with UPS as network slave mode, follow the steps below:
1. Make sure the NVR is connected to the same physical network as the network
UPS master.
2. Select the option “Enable UPS Support”.
3. Select “Network UPS slave” from the “Protocol” drop down menu.
4. Enter the IP address of the network UPS server.
5. Choose between whether the NVR will shut down or enter auto-protection
Commentaires sur ces manuels